| Product Type | Raw Material |
|---|---|
| Product Categories | PP |
| CAS NO. | 9003-07-0 |
| Manufacturers | Sipchem |
| Grade | 1101 SC |
| Place of Origin | Saudi Arabia |
| Appearance | Natural |
| Packing Size | 25/KG Standard Packaging |
| Import | YES |
| Usage level | Car Parts, Food Grade, Medical Grade |
| Feature level | High Temperature Resistance, Aging Resistance |
| Processing Method | Injection Molding |
| Shape | Particle |
Advanced-PP 1101 SC is a polypropylene homopolymer fibre grade characterized by very high flowability, very narrow molecular weight distribution and medium crystallinity providing excellent and consistent process and product behavior.
Advanced-PP 1101 SC is especially suitable for the production fine titer spunbond nonwovens at high speed production lines used for hygiene application.
The product comprises an Advanced-PP phenol free stabiliser package providing high gasfading resistance and inherent basic UV-stability.
| Test Method | ISO 1133 |
|---|---|
| Test Condition | 230℃/2.16kg |
| Test Unit | g/10min |
| Test Result | 35.0 |
| Test Method | ISO 1183 |
|---|---|
| Test Condition | - |
| Test Unit | g/cm³ |
| Test Result | 0.91 |
| Test Method | ISO 527-2 |
|---|---|
| Test Condition | 1mm/min |
| Test Unit | MPa |
| Test Result | 1450 |
| Test Method | ISO 527-2 |
|---|---|
| Test Condition | 50mm/min |
| Test Unit | MPa |
| Test Result | 34 |
| Test Method | ISO 527-2 |
|---|---|
| Test Condition | 50mm/min |
| Test Unit | % |
| Test Result | 8 |
| Test Method | ISO 527-2 |
|---|---|
| Test Condition | 50mm/min |
| Test Unit | % |
| Test Result | >50 |
| Test Method | ISO 179/1eU |
|---|---|
| Test Condition | 23℃ |
| Test Unit | kJ/m² |
| Test Result | 100 |
| Test Method | ISO 179/1eA |
|---|---|
| Test Condition | 23℃ |
| Test Unit | kJ/m² |
| Test Result | 2.5 |
| Test Method | ISO 2039 |
|---|---|
| Test Condition | H 358/30 |
| Test Unit | MPa |
| Test Result | 70 |
| Test Method | ISO 3146 |
|---|---|
| Test Condition | HDT/B ( 0.45 Mpa) |
| Test Unit | ℃ |
| Test Result | 163 |
| Test Method | ISO 75-2 |
|---|---|
| Test Condition | VST/A50 (10 N) |
| Test Unit | ℃ |
| Test Result | 85 |
| Test Method | ISO 306 |
|---|---|
| Test Condition | - |
| Test Unit | ℃ |
| Test Result | 154 |